TUBE & PIPE TECHNOLOGY NOVEMBER 2016

MAC system tests for eccentricity during tube drawing ECCENTRICITY, where the OD and ID are not concentric, is a problem that is most often created during extrusion of the billet before being drawn into a tube. Magnetic Analysis Corporation has recently installed a new Echomac® ultrasonic test system to measure eccentricity at a US copper tube mill that manufactures commercial and industrial grade tube and pipe. The company needed a way to measure eccentricity in a 2.125" OD master tube with 0.1" wall thickness, at speeds up to 600ft/min.

The UT inspection takes place after the extrusion process but while the tube is being drawn in a high-speed draw production line, prior to further reduction. Eccentricity in the finished product can mean wall thicknesses that do not meet specifications, causing problems during further processing downstream. This test alerts the processor to this condition, and they can also use the test results to make adjustments to the process to improve concentricity.

The Echomac® system supplied uses four transducers spaced 90° around the tube. This allows a very accurate calculation of eccentricity of a non-concentric tube, assuming the external and internal extrusion dies are round. A unique mechanical design is used that allows the transducers to track tube movement off-centre.

Test head for the Echomac® ultrasonic eccentricity test system recently installed at a copper tube mill

The transducer ride shoes use wheels to maintain consistent contact with the tube surface, and a bubbler water system maintains the couplant for the ultrasonic energy. These shoes are mounted to air cylinders that close after tube entry and then retract prior to the tube back end exiting. This approach tracks the tube surface and also prevents possible damage to the transducers and shoes from any misalignment of an incoming tube.

An encoder wheel is also mounted to an articulating air cylinder, allowing accurate tube tracking and measurement for the Echomac® electronics. Springs are attached to all cylinders allowing a fail-safe retraction in the event of system air pressure loss. A urethane wiper assembly is mounted to the backside for water containment.

Four-channel eccentricity testing is a special form of four-transducer operation that is designed to measure wall variation based on four independent measurements made at four fixed points that are separated by 90° each around the tube circumference. The software uses trigonometry to construct a sine function with an offset. The offset is the average of these four wall measurements and is the tube’s nominal wall thickness. The amplitude of the derived sine function represents the wall variation.

Ultrasonic transducers positioned around a copper tube during eccentricity test

Instrument display showing A-scan of each thickness measurement, as well as charted data of two separate eccentricity alarms, min and max wall, and average wall

Eccentricity is an expression of wall variation, but the definition depends on the particular user and their agreement with their customers. An accurate minimum and maximum wall thickness is also derived, irrespective of the circumferential tube orientation under the fixed transducers. At this stage, the tube can have ovality as a characteristic due to draw track gripping, but the eccentricity is an attribute of the wall thickness of the tube, and ovality is ignored.

The raw wall thickness data under each test plane can be displayed for set-up purposes. Each computed channel is processed separately, including thresholds, alarming, and recording. The user may set up four independent eccentricity threshold levels. The software gives five choices of eccentricity calculations to suit various customer methods.

The operator can customize how data is presented by selecting the type of view for each of the four channels. In the Echomac® installation, two channels are set for different eccentricity sort levels while a third is used for a min-max thickness alarm, and the fourth monitors average wall. As proof that this four-channel eccentricity method works, the average wall remains a constant regardless of the tube rotation and eccentricity value and is constant over large production runs.

Magnetic Analysis Corp – USA
Email: info@mac-ndt.com
Website: www.mac-ndt.com

Press release

Related Articles

Testing Small Diameter Nitinol Wire

WIRE & CABLE TECHNOLOGY JANUARY 2017 Testing Small Diameter Nitinol Wire Jean R. Gould, Marketing Manager, Magnetic Analysis Corp., Elmsford, N...

Top Products Of 2016: Rotary Eddy Current Tester

WIRE & CABLE TECHNOLOGY JANUARY 2017 Rotary Eddy Current TesterThe high-speed Rotomac® rotary eddy current tester for small diameter wire and r...

MAC Appoints President/CEO

TUBE PRODUCTS INTERNATIONAL SEPTEMBER 2016 Non-destructive testing technology company Magnetic Analysis Corp (MAC) has promoted Dudley M. Boden to ...

MAC Introduces Improved Ultrasonic Weld Line Tester

INTERNATIONAL METAL TUBE SEPTEMBER 2016 Ultrasonic Weldline Tester with test head conducting production testing of a tube. A separate calibrate tu...